makeporngreatagain.pro
yeahporn.top
hd xxx

Practice Test 1 | AWS Certified Solutions Architect Associate | SAA-C03 | Dumps | Mock Test

55,455

You have an application running in us-west-2 that requires 6 EC2 Instances running at all times. With 3 Availability Zones in the region viz. us-west-2a, us-west-2b, and us-west-2c, which of the following deployments provides fault tolerance if ONE Availability Zone in us-west-2 becomes unavailable? (SELECT TWO.)

A. 2 EC2 Instances in us-west-2a, 2 EC2 Instances in us-west-2b, and 2 EC2 Instances in us-west-2c

B. 3 EC2 Instances in us-west-2a, 3 EC2 Instances in us-west-2b, and no EC2 Instances in us-west-2c

C. 4 EC2 Instances in us-west-2a, 2 EC2 Instances in us-west-2b, and 2 EC2 Instances in us-west-2c

D. 6 EC2 Instances in us-west-2a, 6 EC2 Instances in us-west-2b, and no EC2 Instances in us-west-2c

E. 3 EC2 Instances in us-west-2a, 3 EC2 Instances in us-west-2b, and 3 EC2 Instances in us-west-2c

Explanation:

Answer – D and E

Option D- US West 2a-6 , US West 2b – 6, US West 2c-0

  • If US West 2a goes down, we will still have 6 instances running in US West 2b.
  • If US West 2b goes down, we will still have 6 instances running in US West 2a.
  • If US West 2c goes down, we will still have 6 instances running in US West 2a, 6 instances running in US West 2b.

Option E- US West 2a-3 , US West 2b – 3, US West 2c-3

  • If US West 2a goes down, we will still have 3 instances running in US West 2b and 3 instances running in US West 2c.
  • If US West 2b goes down, we will still have 3 instances running in US West 2a and 3 instances running in US West 2c.
  • If US West 2c goes down, we will still have 3 instances running in US West 2a and 3 instances running in US West 2b.

Option A is incorrect because, even if one AZ becomes unavailable, we will only have 4 instances available. This does not meet the specified requirements.

Option B is incorrect because, when either us-west-2a or us-west-2b is unavailable, you would only have 3 instances available. This does not meet the specified requirements.

Option C is incorrect because, if us-west-2a becomes unavailable, you would only have 4 instances available. This also does not meet the specified requirements.

For more information on AWS Regions and Availability Zones, please visit the following URL:

Note: 
In this scenario, we need to have 6 instances running all the time, even when 1 AZ is down.

Hence options D & E are correct.

Comments are closed, but trackbacks and pingbacks are open.

baseofporn.com https://www.opoptube.com
Ads Blocker Image Powered by Code Help Pro

Ads Blocker Detected!!!

We have detected that you are using extensions to block ads. Please support us by disabling these ads blocker.